Additional branch circuits are to supply other utilization equipment not covered above. Accordingly, the supply wires are protected only for short circuit, and the overload protection is provided closer to the motor. Supports for cables or raceways in a hoistway or in an escalator or moving-walk wellway or platform lift and stairway chairlift runway must be securely fastened to the guide rail, escalator or moving-walk truss, or to the hoistway, wellway or runway construction. 836 Troy Schenectady Road ; Latham, NY 12110 . These are the principle NEC 2011 Article 620 mandates. (Cross-sectional areas of conductors are given in Chapter 9, Tables 5 through 8. f?3-]T2j),l0/%b Other requirements: Spa's and Hot Tubs 1996 NEC 15-20 Amp 120 volt Receptacle Requirements for Dwelling units: All outdoor Doors must open in the direction of travel and be equipped with panic bars, pressure plates or other devices that are normally latched but open under simple pressure. For example, it is stated that the cross-sectional area of the individual conductors in a wireway are not to exceed 50% of the interior cross-sectional area of the wireway. In the event of a breakdown, that phone must automatically call a location staffed 24 hours a day. (B) Lighting Switch. Have wiring identified for use in wet locations in accordance with the requirements in NFPA 70. The most complex of these is the elevator. You are seeing this message for one of three reasons: You have reached your limit of free content. Fluid pressure in the cylinder raises and lowers the elevator cab. The architect has a choice of either traction or hydraulic elevators. NEC has a further note that the term wheelchair lift has been changed to platform lift.. Such design innovations require sophisticated wiring strategies. Provide continuous, non -slip, horizontal rungs every 12" for the full height of the pit ladder. First, the traveling cable must be composed of very fine-stranded conductors so it can flex with a minimum of internal stresses, ensuring long service life and reliability. Society of Mechanical Engineers. or larger, not exceeding 6 ft. in length, are permitted between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means and pumping motors and valves. The fan should be on a dedicated circuit. If your specifications require a vent at the top of the shaft for venting smoke, you must provide a key switch with a pilot light to control that vent. Described below are several work practices that may be used to reduce arc-flash hazards when working on energized equipment: David Herres holds a New Hampshire Master Electricians license and has worked as an electrician in the northern part of that state for many years. Get more of Elevator World. Hoistway pit lighting and receptacles 5. APPENDIX A 2.2. The elevator equipment room that serves a hydraulic elevator is almost always located on the lowest floor adjacent to the elevator shaft. The fire loading resulting from an accumulation of abandoned low-voltage cabling may be considerable, and has to be understood and dealt with. Your IP: Limit switches placed throughout the height of the shaft communicate with the controller and stop the cab at each landing. But, building codes had been in existence for many centuries. Smoke detectors, which are required in all elevator lobbies and elevator equipment rooms, must be connected to the elevator controllers directly by means of auxiliary contacts and wiring, or indirectly by means of output signals from the fire alarm control panel. , !! Hammurabi, sixth king of Babylon and creator of the Babylonian Empire, decreed: If a builder builds a house for someone and does not construct it properly, and the house which he built falls in and kills its owner, then that builder shall be put to death. As recommended in NFPA 70E, the National Elevator Industry, Inc. (NEII) commissioned an arc-flash hazard analysis (in compliance with IEEE Standard 1584-2002 for procedures for calculating the incident energy of the arc flash) by an independent consultant to determine at what level an arc-flash hazard exists to employees who work on energized elevator equipment. 836 Troy Schenectady Road Latham, NY 12110 . Dec. 21, 2010. ^W i word/document.xml=nr]6Id=,_$j9-"Y.iGU\h_}. Second, it must be configured so as to eliminate any chance of tangling or chafing against the inner surface of the hoistway or items mounted on it. The design engineer must identify the available fault current at the elevator controller to the installer so an elevator controller with adequate SCCR can be provided. For this reason, the NEC provides for adequate working space around electrical equipment that may need to be serviced. Granle is a licensed professional engineer with Sebesta Blomberg & Associates, Rochester, Minn. https://www.facebook.com/ElectricalConstructionMaintenanceMagazine, https://www.linkedin.com/company/electrical-construction-maintenance/, ABCs Construction Backlog Indicator Down to Start 2023, The Most Popular Code Quizzes of the Week from 2021, The 10 Most Popular Photo Galleries of 2021, Whats Wrong Here? After reading this article, you should have learned: Which locations require sepa-rate, dedicated branch circuits Which branch circuits are not to be provided with ground fault circuit interrupter (GFCI) pro-tection Which locations must have one or more duplex receptacles Where overcurrent protection for hoistway, pit and machine-room lighting must be located How unsupported lengths of traveling cables are measured. Next, with multiple elevator banks, the controller will usually allow only one elevator at a time to operate, reducing the amount of emergency power required. These 29 CFR 1910.146 (c) (8) requirements are: This may be countered by providing good machine-room ventilation. In these installations, it is best to design the elevator controller so the elevator controller SCCR is adequate for the available fault current. The cover shall be secured and level with the pit floor. We shall now take a look at the principle requirements of Article 620, with particular emphasis on wiring requirements for elevator shafts, machine rooms and cars. Besides the initial determination requirement of paragraph (c) (1), the "host" employer must comply with the five (5) requirements of paragraph (c) (8) when engaging another employer (contractor) who will have employees in permit spaces under the control of the host employer. Many professionals believe the NEC is applicable only for voltages over a certain level, but that is not the case. And as the designer, you can become the fulcrum on which all of these requirements and authorities exert their leverage, but an understanding of elevator basics can help you handle the pressure. endstream
endobj
954 0 obj
<. As always, the best advice in all instancesdo your homework, communicate often, and document decisions made. It employs specialists in Mobile, Alabama, and has technical and news correspondents around the world. Traction elevators are typically faster and more energy efficient than hydraulic elevators, and are often used for high-rise buildings. Freight Elevator Door Control: An Opportunity for Wireless Technology. If the equipment must remain energized to perform work, effective insulation and safe electrical working practices should be observed. You need to Subscribe to continuing reading. Motors for traction elevators were traditionally DC or synchronous, but new installations use AC motors and VFDs for speed control. NEC specifies Hoistway wiring, and doesn't seem to distinguish between hoistway and pit. Thus, the need for door interlock functionality is recognized. The AHJ is saying that this is a violation of 620.23. Section 620.85, GFCI Protection for Personnel, provides that 125-V, single-phase, 15- and 20-amp receptacles installed in pits, hoistways, machinery spaces, machine rooms, escalators and moving walks, and on elevator car tops are to be GFCIs. GET YOUR CEUS TODAY, 1998-2021. You'll be responsible for specifying the items related to the fire alarm and some controls, as well as supplying lighting and power to the equipment room and elevator pit. Convenience receptacles and lighting for maintenance purposes are required at the base of the pit and, in some instances (elevator manufacturer dependent), at the top of the elevator shaft. We generally think of the 19th century as the great age of building codes. Elevator travel is far safer than an automobile trip, and the chance of experiencing disaster is on the order of being struck by lightning in ones own backyard. Through numerous editions, the NEC has, to a great extent, mitigated the hazards accompanying widespread use of electricity, particularly with respect to elevator technology. Use Underwriters Laboratories or Canadian Standards Association-labeled scopes tested for 1,000 V. Lockout/tagout: When troubleshooting is complete and further work can be accomplished without the equipment being energized, follow the lockout/tagout procedures in Section 7 of the. Motor controllers are permitted outside the spaces specified above. Similarly, underground wiring in mines is not NEC regulated, although other, non-mine wiring below ground (such as lighting in an underground traffic tunnel) is covered. (ASME has a separate document, A18.1-2008 Safety Standard for Platform Lifts and Stairway Lifts). Many NEC articles address voltage limitations, and Article 620 is no exception. In some cases, it may require a means to test the shunt trip operation or have one contact operate the shunt trip of more than one elevator. charlie b. If a smoke detector goes into alarm, it signals the elevator to go into Fire Recall Function, at which point the controller directs the elevator cab to travel to its pre-programmed designated landing, open its doors, and remain stopped there until the alarm clears. In hoistways not longer than 6 ft., these additional wiring methods are permitted: A sump or oil-recovery pump located in the pit is permitted to be cord connected. Since 1953, Elevator World, Inc. has been the premier publisher for the global vertical transportation industry. Additional requirements concern escape routes. It need not be exactly centered on the equipment, and working spaces of adjacent pieces of equipment may overlap. Of particular importance is the location of the disconnecting means so it can be found by an individual who may not be familiar with the installation. endstream
endobj
startxref
Therefore, there will be two signals to the elevator control panel related to smoke detectors: one from the designated floor smoke detector and another combined signal from the smoke detectors at the other lobby landings and in the equipment room. NEC Guidelines on Commercial Garages. This is important as the tradition of using only time-current curves for the analysis of overcurrent device operation is usually not sufficient since the time-current curves traditionally stop at 0.01 second (not time zero). In this case, it may be best if the elevator controller manufacturer does not include the elevator disconnecting means (often offered as a circuit breaker) but instead have the installer provide a separate fused disconnect to comply with NEC 620.51(A) and also achieve a high SCCR for the elevator controller when fuses are provided as specified by the elevator controller and marked on the elevator controller nameplate. Corporate Office These must also be insulated for the maximum voltage applied to any conductor within the cable or raceway system. A little more narrowly focused (yet of great consequence) is the ubiquitous NEC, which, in the National Fire Protection Association (NFPA)s venerable Handbook edition, devotes 18 double-column pages to electrical design and installation requirements for elevators, escalators and related equipment. The thinking behind this requirement is that the injured worker could have severe hand burns and be unable to operate a conventional doorknob. For instance, a typical elevator controller may traditionally have SCCR ratings from 5 to 10 kA. The branch circuit is to be protected by an overcurrent device located in the machine room, control room/machinery space or control space. Regardless of the number of elevators, only one smoke detector is required at each floor lobby, but it must be located within 21 ft of every elevator door. Traditionally, the electrical system design engineer has given little attention to the elevator controller. The feeder OCPD needs to remain closed so the remaining elevators have power and continue to function. Elevator power disconnect (with utility feed marking) located in the machine room or other permitted location David Herres David Herres holds a New Hampshire Master Electrician's license and has worked as an electrician in the northern part of that state for many years. (g) Stop Switch in Pits. He is saying that each pit requires a separate circuit, in other words "dedicated". Though I understand how someone might argue two. The main impetus for the creation of the NEC in the closing years of the 19th century was the collective anguish experienced by insurance underwriters who were losing vast amounts of money due to liability and physical damage claims resulting from Edisons electrification of, first, Lower Manhattan and then the world. Installing electrical equipment where its SCCR is less than the available short-circuit current creates serious safety hazards. It is of great importance that power to the various elevator functions can be quickly and reliably removed from the loads in case of emergency or for maintenance and troubleshooting. Lights and convenience outlets in elevator pits shall be installed to comply with the requirements of CCR, Title 24, Part 3, Article 620. It is of great importance for the design engineer to communicate with their local authority having jurisdiction (AHJ) to determine fire alarm requirements for the respective elevator installation. As we have seen, a limited number of these are approved for elevator locations car, hoistway, pit and machine room.
One. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. It is further stated that the disconnecting means are not to disconnect the branch circuits required in sections 620.22, 620.23 and 620.24. This accomplishes two functions. After such an event, it is important that the affected worker is able to escape the area and get to help. Elevator cab lights require emergency back-up power. The same figure applies to nonmetallic wireways. They are permitted to be run without raceway when used inside the hoistway, on the elevator car, hoistway wall, counterweight, or controllers and machinery located inside the hoistway, provided they are in their original sheaths. It is worth noting that these NEC terms, used throughout Article 620, have been chosen to correlate with A17.1-2007 usage. 2023 Endeavor Business Media, LLC. Something went wrong. The surest means of avoiding an arc-flash hazard is to lockout and tagout the electrical service to a controller. And so the needs can be very different. 1993 NEC 15-20 Amp 120 volt Receptacle Requirements: Wet bar sinks, all bathrooms, roof tops, elevator machines rooms, elevator car tops, elevator pits. The cord is to be a hard-usage, oil-resistant type not over 6 ft. in length. Selective coordination is also required for multiple elevators per NEC 620.62. Feeders may be installed within the hoistway where the elevator has a driving-machine motor in the hoistway or on the car or counterweight. The sum of the cross-sectional area of the individual conductors in raceways is not to exceed 40% of the interior cross-sectional area of the raceway, except as permitted for wireways. It is noted that the article covers the installation of electrical equipment and wiring for elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. z!0: - [Content_Types].xml ( n0EUb*>-RxV=QUAl"93dFk%Y?l}MGDV from components that are not otherwise guarded. CLAIMED . A raceway that comes loose on the inside of a hoistway could catch on a moving car, causing immense damage and hazard to users. Part III, Wiring, looks at the types of wiring that may be installed in hoistways, cars, machine rooms and related spaces. This is something that can be easily accomplished if the elevator controller manufacturer uses components in combination with overcurrent protective devices that are tested and listed with high combination SCCRs. The proposals resulted in adding new requirements in the 2017 NEC for: This article will also discuss other Code requirements that include selective coordination for elevators that are supplied by emergency, legally required standby or critical operation power systems or multiple elevators supplied from a single feeder, and shunt tripping of elevators where the elevator equipment room and/or shaft has a fire suppression sprinkler system. Elevators with driving machines located on the car or counterweight, or in the hoistway are permitted outside the specified spaces. 988 0 obj
<>stream
Later in the 19th century, Thomas Edison and his associates built an electrical distribution system in Lower Manhattan.